SSBTSURFUiBzb25vIGludGVycnV0dG9yaSBzZXppb25hdG9yaSBhIDMgbyA0IHBvbGkgYSBjb21hbmRvIG1hbnVhbGUuPGJyIC8+DQpUYWxpIGRpc3Bvc2l0aXZpIGdhcmFudGlzY29ubyBs4oCZYXBlcnR1cmEgbyBsYSBjaGl1c3VyYSBzb3R0byBjYXJpY28gZSBpbCBzZXppb25hbWVudG8gZGkgc2ljdXJlenphIGRpIHF1YWxzaWFzaSBjaXJjdWl0byBlbGV0dHJpY28gaW4gYmFzc2EgdGVuc2lvbmUu

Caratteristiche tecniche

Altezza [mm] 300
Larghezza [mm] 475
Profondità [mm] 201
Peso [kg] 12.76
Tipo di controllo Direct : J3 / External : S3
Numero di poli 4
Tensione nominale 690 VAC - 500 VDC
Corrente nominale [A] 630
Tipo Lateral operation
Taglia della scatola 6

Classificazione

UNSPSC 39122233
Classe ETIM EC000216
IGCC 5290

Commercio

Descrizione Interruttore manuale con interruzione visibile SIDER a 4 poli 630A 690VAC-500VDC azionamento laterale diretto con maniglia tipo J3 o laterale esterno con maniglia tipo S3. Fornito senza maniglia
Data di entrata in vigore 1988-04-15
Codice del ciclo di vita dell'offerta 40
Paese d'origine FR

ETIM - Caratteristiche elettriche

Max. tensione d’esercizio nominale Ue per AC [V] 690
Tensione d’esercizio nominale [V] 400..690
Corrente nominale permanente Iu [A] 630
Corrente nominale permanente a AC-23, 400V [A] 630
Corrente nominale permanente per AC-21, 400 V [A] 630
Resistenza a corrente di breve durata Icw [kA] 26
Potenza d’esercizio nominale per AC-23, 400V [kW] 375
Potenza di interruzione a 400 V [kW] 375
Corrente di corto circuito nominale condizionale Iq [kA] 100
Numero di poli 4

ETIM - Caratteristiche meccaniche

Adatto per fissaggio a pavimento No
Adatto per fissaggio frontale a 4 fori Si
Adatto per fissaggio frontale centrale No
Adatto per montaggio distributore No
Adatto per costruzione intermedia Si
Colore dell’elemento di azionamento Altro
Grado di protezione (IP), lato frontale IP20
Larghezza [mm] 475
Altezza [mm] 300
Profondità [mm] 201

ETIM - Caratteristiche tecniche

Esecuzione come interruttore principale Si
Esecuzione come interruttore di manutenzione/riparazione Si
Esecuzione come interruttore di sicurezza Si
Esecuzione come dispositivo di arresto d’emergenza Si
Esecuzione come invertitore No
Numero di interruttori 1
Azionamento a motore opzionale No
Azionamento a motore integrato No
Sganciatore di tensione opzionale No
Tipologia costruttiva dell'apparecchio tecnica dell'incorporazione fissa del dispositivo incorporato
Tipologia di azionamento Altro
Bloccabile Si
Tipo di collegamento circuito elettrico principale Connessione a bullone

Logistica

GTIN/EAN 3596031143207
Numero doganale 8536508000
Unità di prezzo PC
Peso dell'unità di imballaggio [kg] 12.76
Lunghezza dell'unità di imballaggio [m] 0.3
Larghezza dell'unità di imballaggio [m] 0.3
Profondità dell'unità di imballaggio [m] 0.4

Norme

Conformità alle norme IEC
  • PDF
    SIDER & SIDER ND_UE declaration
    Selezionare
  • PDF
    Sider & Sider ND_UK declaration
    Selezionare

Riferimenti

SIDER è disponibile in 64 versioni

Codice Tipo Corrente nominale [A] Numero di poli Taglia della scatola Tipo di controllo Tensione nominale Aggiungi alla selezione
29213012 Front or lateral operation 125 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29153012 Lateral right operation 125 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29214012 Front or lateral operation 125 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29154012 Lateral right operation 125 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29003063 Front operation 630 3 6 Direct : J3 / External : S3 690 VAC - 500 VDC
29004063 Front operation 630 4 6 Direct : J3 / External : S3 690 VAC - 500 VDC
29003080 Front operation 800 3 6 Direct : J3 / External : S3 690 VAC - 500 VDC
29004080 Front operation 800 4 6 Direct : J3 / External : S3 690 VAC - 500 VDC
29003120 Front operation 1250 3 7a Direct : J3 / External : S3 690 VAC - 500 VDC
29004120 Front operation 1250 4 7a Direct : J3 / External : S3 690 VAC - 500 VDC
29213020 Front or lateral operation 200 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29003160 Front operation 1600 3 7b Direct : J3 / External : S3 690 VAC - 500 VDC
29153021 Lateral right operation 200 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29004160 Front operation 1600 4 7b Direct : J3 / External : S3 690 VAC - 500 VDC
29214020 Front or lateral operation 200 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29154021 Lateral right operation 200 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29053063 Lateral operation 630 3 6 Direct : J3 / External : S3 690 VAC - 500 VDC
29053080 Lateral operation 800 3 6 Direct : J3 / External : S3 690 VAC - 500 VDC
29054080 Lateral operation 800 4 6 Direct : J3 / External : S3 690 VAC - 500 VDC
29053120 Lateral operation 1250 3 7a Direct : J4 / External : S4 690 VAC - 500 VDC
29054120 Lateral operation 1250 4 7a Direct : J3 / External : S3 690 VAC - 500 VDC
29213025 Front or lateral operation 250 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29053160 Lateral operation 1600 3 7b Direct : J3 / External : S3 690 VAC - 500 VDC
29153025 Lateral right operation 250 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29054160 Lateral operation 1600 4 7b Direct : J3 / External : S3 690 VAC - 500 VDC
29214025 Front or lateral operation 250 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29154025 Lateral right operation 250 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29003121 Front operation 1250 3 7a Direct : J4 / External : S4 690 VAC - 500 VDC
29013181 Front operation 1800 3 7c Direct : J4 / External : S4 690 VAC - 500 VDC
29013201 Front operation 2000 3 2x7a Direct : J4 / External : S4 690 VAC - 500 VDC
29013251 Front operation 2500 3 2x7a Direct : J4 / External : S4 690 VAC - 500 VDC
29013321 Front operation 3200 3 2x7b Direct : J4 / External : S4 690 VAC - 500 VDC
29216020 Front or lateral operation 200 6 Direct : F2 / External : S2 690 VAC - 500 VDC
29203012 Lateral left operation 125 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29204012 Lateral left operation 125 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29213031 Front or lateral operation 315 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29103021 Lateral left operation 200 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29153031 Lateral right operation 315 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29203021 Lateral left operation 200 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29214031 Front or lateral operation 315 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29204021 Lateral left operation 200 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29103025 Lateral left operation 250 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29203024 Lateral left operation 250 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29203025 Lateral left operation 250 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29204025 Lateral left operation 250 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29103041 Lateral left operation 400 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29203041 Lateral left operation 400 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29213041 Front or lateral operation 400 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29104041 Lateral left operation 400 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29153041 Lateral right operation 400 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29204041 Lateral left operation 400 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29214041 Front or lateral operation 400 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29154041 Lateral right operation 400 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29204051 Lateral left operation 500 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29053013 Lateral operation 125 3 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29056013 Lateral operation 125 6 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29053020 Lateral operation 200 3 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29056020 Lateral operation 200 6 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29053040 Lateral operation 400 3 5 Direct : F2 / External : S2 690 VAC - 500 VDC
29053050 Lateral operation 500 3 5 Direct : F2 / External : S2 690 VAC - 500 VDC
29213051 Front or lateral operation 500 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29153051 Lateral right operation 500 3 Direct : F2 / External : S2 690 VAC - 500 VDC
29214051 Front or lateral operation 500 4 Direct : F2 / External : S2 690 VAC - 500 VDC
29154051 Lateral right operation 500 4 Direct : F2 / External : S2 690 VAC - 500 VDC